Solar PV Generation - Live Performance Data
17-01-2023 - Tesla Powerwall2 installed
12-01-2023 Offline till 11:00 as string 2 solar panels being replaced with 5 Trina Vertex S panels
Week begining 16-01-2023 Tesla Power Wall to be installed
Newquay Weather - Solar PV Generation | ||||||
---|---|---|---|---|---|---|
SkyCam - North |
Power One 3.6 PVI OUTD | |||||
Inverter Status - ONLINE | ||||||
23 December 2024 | Sunrise : 08:17 | Sunset : 16:21 | ||||
Max Daylight Hours : 08:00 hours 11 | To listen, click speaker icon top left |
|||||
Inverter Data : Updated Every 2 Minutes | ||||||
1 - Week starts Sunday 2 - install date 4/2/2012 3 - Slight difference of 40 W 4 - UK Model (G83) 5 - For other codes see manual |
6 - Data entered manually, inverter data 7 - Efficiency, power out / string total % 8 - GMT all year 9 - Alarms Checked 0900,1200,1500,1800 Reset after check |
10 - C02 conversion factor is 0.542 kg CO2 saved per kWh 11 - Time between sunrise and sunset 12 - Davis VP2 solar sensor from 8/2/2018 13 - Immersion heater - Solar pv |
||||
Last Update | 23-12-2024 11:06 | String 1 | 121 W | Grid Voltage | 243.6 V | |
Generation Start Time | 23-12-2024 08:18 | 215 V | Av Grid Voltage | 244.4 V | ||
Generation Stop Time | --- | 0.6 A | Grid Current | 1.0 A | ||
Energy Today inverter data | 0.343 kWh | String 2 | 125 W | Grid Freq | 49.9 Hz | |
Energy Week 1 | 3.843 kWh | 198 V | Peak Power Today | 260 W | ||
Energy Month | 52.283 kWh | 0.6 A | Peak Power Ever 4 | 3627 W | ||
Energy year 2 | 4074.351 kWh | Total | 246 W | Internal Temp | 20.9 C | |
Energy lifeTime 3 | 54636.197 kWh | Power Out | 240 W | Isolation Resistance | 20.00 MΩ | |
Min Day Energy 6 | 10/12/2016 - 27 W | Efficiency 7 | 97.56 % | Dc/Dc Current Leak | 6.3 mA | |
Max Day Energy 6 | 8/6/2015 - 28.9 kW | Inverter Current Leak | 6.3 mA | |||
Solar Radiation 12 | 23-12-2024 11:07 | 60 W/m2 | Inverter Time 8 | 11:04 GMT | ||
Immersion Heater 13 | [148] 22-12-2024 12:42 OFF | CO2 Saved Year10 | 2208 kg | |||
Alarm Code 5 | No Alarm | CO2 LifeTime10 | 29613 kg | |||
Last 4 Alarms Codes 9 | Last check 0900 | 11 | 11 | 11 | 11 | |
Last Alarm Code | 19-11-2024 08:06, 15 Code: 15 |
Alarm codes in pop up window Here Some alarm codes shown only on Aurora display panel.
Solar Graphs available from 12th February 2012.Default todays graph if availableLatest -17-01-2023 - Tesla Wall fitting, interruptions to mains so no generation for some of the day 12-01-2023 - Offline till 11:00 as string 2 solar panels being replaced with 5 Trina Vertex S panels. 16-11-2022 - Down from approx 12:34 to 13:24, Smart meter fitted 14/18-03-2022 - No solar pv data for 4 days, webserver upgrade total mess, back online 10:32 18/03/2022 12-3-2022 - String 2 (SunTech) Ground fault, 0.56 MOhm, switched off temporary 2-3-2022 - String 1 (LG) tripping mains out, switched off temporary 5-3-2020 - String 1 (LG) ground fault, 0.54 MOhm, back online 10:24 5-3-2019 - Western Power doing work on low voltage lines, power off, no solar generation from 10:00 to 15:45 23-3-2018 - Added year comparison graph 18-3-2018 - Snow covered panels from 14:58, no output, no output till 16:34, then stopped at 16;48 again 13-2-2018 - Added W/m2 to todays graph 8-2-2018 - Davis VP2 solar radiation sensor added 12-1-2018 - WS2300 Weather station changed to Davis VP2 Pro, which isn't affected by leakage 22-12-2017 - String 2 causing gust spikes on weather station when leakage 0ver 6mA, turned off when bad 2-11-2017 - Fault Found on string 1, connector termination fault 23-10-2017 - 2-11-2017 Ongoing - String 1, faulty, off line alot , ground fault, less than 1 MOhm 21-9-2017 - New LG panels, string 1 ground fault, 0.2 MOhm, Online 11:42 17-8-2017 - String 1 ground fault, 0.48 MOhm, Online 08:58 26-7-2017 - New LG String 1, ground fault 1.11 MOhm, string 2, 20 MOhm. Online 08:44 now string 1, 2.55 MOhm 5-4-2017 - 08:42 to 11:06 string 1, 8 SunTech panels replaced with 7 LG panels 28-2-2017 - Installers faulting string 1, found 2 faulty panels, others have low readings Only 6 panels connected string 1 12-1-2017 - Installers Faulting, Inverter OK, panel checking tomorrow 20-11-2016 - PAY BACK approx 09:30 took 4 years 9 months 17 days 13-9-2016 - String 1, faulty low Riso all day 0.62 MOhm 4-7/9/2016 - String 1, faulty, Risco below 1 mohm, wet, back online when drier in day 12/8/2016 - Cornwall Solar on site, faulting string 1 panels 2/8/2016 - Rain for hours, string 1 Riso 0.39 mOhm, switched off 19-22/2/2016 - String 1 still faulty when wet, string 2 fixed 18/2/2016 - Engineers onsite, faulting, fault loose connection in inverter 13/2/2016 - Ground fault, both strings, inverter switched off 4/1/2016 - Cornwall Solar - String One faulty, 1 mOhm, 20 mA, disconnected, waiting for date to replace connectors on roof 3/1/2016 10:30 Back on, Risco and leakage within limits 2/1/2015 08:30 Inverter tripping fuse box, low Risco and leakage, switched off 22/12/2015 - Tripped Fusebox - Cornwall solar rang to book visit, 12mA leakage, reset OK 24/7/2015 - Inverter offline, low riscoe alarm 0.57 Mohm, cleared 08:46 30/1/2015 - Added monthly total and daily average to month graph Solar PV Log Full list |
Month and Year graph now updated every 2 minutes
2022 Data Graph, updated end of day
Hover mouse over for dataComparing Years
Yearly Comparison Graph - Scroll / Hover mouse over for data - live data from 4th Feb 2012
NOTE: 2012 From Feb 4th Installtion Completion and 2016 / 2017 - Some days only one string
Shading of photovoltaic panels is one of the most significant causes of losses in a pv system. In fact, the shading of 10% of the area of a system could cause a
loss of 50%. This disproportionate effect is caused by string design. If there is one shaded panel in the string, the whole string underperforms.
There are few software solutions to gaining access to the inverter data, all require the use of a pc.
The inverter comes with Aurora Communnicator CD pdf manual,
there is also Aurora Monitor, a Java application, Aurora Monitor
and a command-line program for Linux Aurora
My aim was to write php scripts to run on the server, which will do away with the need for a home pc, the script is called by a cron job every 2 mins, generate the data as seen below and also produce graphs. See the eNet-232 Ethernet to Serial converter section below for more information.
5-4-2017 - 8 Suntech panels string 1, being replaced with 7 LG panels from 08:42 to 11:06
20-11-2016 - PAY BACK approx 09:30 took 4 years 9 months 17 days, based on FIT payments only
My aim was to write php scripts to run on the server, which will do away with the need for a home pc, the script is called by a cron job every 2 mins, generate the data as seen below and also produce graphs. See the eNet-232 Ethernet to Serial converter section below for more information.
5-4-2017 - 8 Suntech panels string 1, being replaced with 7 LG panels from 08:42 to 11:06
20-11-2016 - PAY BACK approx 09:30 took 4 years 9 months 17 days, based on FIT payments only